Technical Specification:
Refrigeration Capacity:
80.0 kW/68.800 kcal/h or 1.651.000 kcal per 24 hours*.
Variable production range:
Output can be varied from 1.845 L/h with 40% ice concentration to 6.320 L/h with 10% ice concentration**.
Filtration:
A 5-micron filter fitted to water intake to prevent ingestion of foreign objects.
Minimum salt concentration:
System requires 3% NaCl concentration for Optim-Ice® production
Power Consumption:
40.0 kW
Dimensions in cm (LxWxH):
286x136x173
Weight:
1.800
Refrigerant:
R-404A /R-449A
Pre-Cooler:
Optional pre-cooler ensures uniform production of Optim-Ice® over a large inlet water temperatures range.
Condenser:Cooling water requirements:5°C = 5.200 L/h10°C = 6.900 L/h15°C = 9.500 L/h20°C = 20.000 L/h