Technical Specification:

Refrigeration Capacity:

90.0 kW/77.375 kcal/h or 1.857.000 kcal per 24 hours*.

Variable production range:

Output can be varied from 920 L/h with 40% ice concentrationto 2.210 L/h with 10% ice concentration**.

Filtration:

A 5-micron filter fitted to water intake to prevent ingestion of foreign objects.

Minimum salt concentration:

System requires 3% NaCl concentration for Optim-Ice® production.

Power Consumption:

52.0 kW

Dimensions in cm (LxWxH):

166x136x173

Weight:

1.150 kg

Refrigerant:

R-404A /R-449A

Pre-Cooler:

Optional pre-cooler ensures uniform production of Optim-Ice® in water temperatures up to +32°C.

Condenser:Cooling water requirements:5°C = 3.600 L/h10°C = 4.500 L/h15°C = 6.000 L/h20°C = 11.700 L/h32°C = 27.800 L/h

* Appr. 1 kcal is required to achieve a one-degree temperature reduction in one kilogram of fish. ** Based on seawater inlet temperature of +32°C.