Technical Specification:

Refrigeration Capacity:

80.0 kW/68.800 kcal/h or 1.651.000 kcal per 24 hours*.

Variable production range:

Output can be varied from 1.845 L/h with 40% ice concentration to 6.320 L/h with 10% ice concentration**.

Filtration:

A 5-micron filter fitted to water intake to prevent ingestion of foreign objects.

Minimum salt concentration:

System requires 3% NaCl concentration for Optim-Ice® production

Power Consumption:

40.0 kW

Dimensions in cm (LxWxH):

286x136x173

Weight:

1.800

Refrigerant:

R-404A /R-449A

Pre-Cooler:

Optional pre-cooler ensures uniform production of Optim-Ice® over a large inlet water temperatures range.

Condenser:Cooling water requirements:5°C = 5.200 L/h10°C = 6.900 L/h15°C = 9.500 L/h20°C = 20.000 L/h

* Appr. 1 kcal is required to achieve a one-degree temperature reduction in one kilogram of fish. ** Based on seawater inlet temperature of 0°C.